The REVEXmax S (STANDARD) / REVEXmax W (WELD) is a professional, compact, portable analyzer, designed to verify the electrical safety of appliances or arc welding equipments (WELD variant only). The REVEXmax has an extraordinary wide scope of use thanks to a lot of optional accessories, which enable testing practically any portable or hard-wired, one-phase or three-phase appliance.

REVEXmax W

General description:

The REVEXmax S (STANDARD) / REVEXmax W (WELD) instrument is designed to verify the safety of electrical appliances in general. All AC measurements are measured by the method TRMS (true rms), and for some measurements the DC component value can be displayed. Measured circuits meet the requirements of EN 61557 and EN 60974-4 (requirements for measuring circuits), including the required input characteristics.

The REVEXmax performs the following tests:

  • Earth bond test >1 A AC
  • Insulation resistance test 500 V DC and 250 V DC
  • Alternative (substitute) leakage current
  • PE current during operation and touch leakage current
  • Differential leakage current and touch leakage current
  • Apparent power
  • Mains voltage
  • Current consumption
  • Welding equipments output voltage and leakage current (WELD variant only)
  • External voltage (WELD variant only)

Download manual (EN) 

Download REVEXmax declaration of conformity

 

Technical specification:

Notes: R - reading, D - digit

Earth bond:

 Entire measuring range [Ω]  0,000 ÷ 10,00
 Measuring range [Ω]  0,000 ÷ 0,999  1,00 ÷ 10,00
 Resolution [Ω]  0,001  0,01
 Reference error  ± (2 % of R + 6 D)  ± (2 % of R + 5 D)
 Operating error  ± (3 % of R + 8 D)  ± (3 % of R + 7 D)
 Operating range of use [Ω]  0,030 ÷ 10,00
 Open - circuit voltage  5 ÷ 12 V AC
 Test current (R ≤ 1 Ω)  > 1 A AC
 Test lead compensation  yes (up to 2 Ω)

Insulation resistance:

 Entire measuring range [MΩ]  0,20 ÷ 100,0
 Measuring range [MΩ]  0,20 ÷ 19,99  20,0 ÷ 100,0 
 Resolution [MΩ]  0,01  0,1
 Reference error  ± (2 % of R + 2 D)  ± (4 % of R + 15 D)
 Operating error  ± (3 % of R + 3 D)  ± (5 % of R + 15 D)
 Operating range of use [MΩ]  0,20 ÷ 100,0
 Nominal output voltage  500 / 250 V DC
 Nominal test current  ≥ 1 mA DC
 Short - circuit current  < 10 mA DC
 Self - test  2,00 ± 0,05 MΩ

Alternative leakage current:

 Entire measuring range [mA]  0,00 ÷ 20,00
 Resolution [mA]  0,01
 Reference error  ± (2 % of R + 2 D)
 Operating error  ± (3 % of R + 3 D)
 Operating range of use [mA]  0,10 ÷ 20,00
 Nominal open - circuit test voltage  230V ± 15 %, 50 Hz ± 0,5 Hz
 Short - circuit current  < 3,5 mA
 Internal resistance
 of test voltage source
 > 80 kΩ
 Self - test  0,10 ± 0,01 mA

Direct leakage current:

 Entire measuring range [mA]  0,00 ÷ 10,00
 Resolution [mA]  0,01
 Reference error  ± (2 % of R + 2 D)
 Operating error  ± (3 % of R + 3 D)
 Operating range of use [mA]  0,10 ÷ 10,00
 Test voltage  line voltage
 Frekvency charakteristic
 of internal test circuitry
 according EN 61557
 Self - test  0,10 ± 0,01 mA

Differential leakage current:

 Entire measuring range [mA]  0,00 ÷ 10,00
 Resolution [mA]  0,01
 Reference error  ± (2 % of R + 3 D + *X)
 Operating error  ± (3 % of R + 4 D + *X)
 Operating range of use [mA]  0,25 ÷ 10,00
 Test voltage  line voltage
 Frekvency charakteristic
 of internal test circuitry
 according EN 61557
 Self - test  0,10 ± 0,01 mA

*X = S (0,001 IΔ + 0,001) [D]
S ... Apparent power of tested appliance [VA]
IΔ ... Displayed value of leakage current [mA]

Leakage current by means of three-phase adapter:

 Entire measuring range [mA]  0,00 ÷ 20,00
 Resolution [mA]  0,01
 Reference error  ± (3 % of R + 10 D) 1)
 Operating error  ± (4 % of R + 15 D) 1)
 Operating range of use [mA]  0,58 ÷ 20,00

Apparent power:

 Entire measuring range [VA]  10 ÷ 3680
 Resolution [VA]  1
 Reference error  ± (3 % of R + 2 D)
 Operating error  ± (5 % of R + 5 D)

 Mains voltage UL-N:

 Entire measuring range [V]  207,0 ÷ 253,0
 Resolution [VA]  0,1
 Reference error  ± (1 % of R + 2 D)
 Operating error  ± (2 % of R + 2 D)

Current consumption:

 Entire measuring range [A]  0,0 ÷ 16,0
 Resolution [A]  0,1
 Reference error  ± (2 % of R + 1 D)
 Operating error  ± (3 % of R + 2 D)

 Current consumption by means of current clamp:

 Entire measuring range [A]  0,0 ÷ 100,0
 Resolution [A]  0,1
 Reference error

 ± (3 % of R + 4 D)1)

 Operating error  ± (4 % of R + 4 D)1)

Apparent power by means of durrent clamp:

 Entire measuring range [VA]  10 ÷ 9999
 Resolution [VA]  1
 Reference error  ± (5 % of R + 5 D)1)
 Operating error  ± (8 % of R + 5 D)1)

External voltage DC (WELD variant only):

 Entire measuring range [V]  0,0 ÷ 130,0
 Resolution [V]  0,1
 Reference error  ± (2 % of R + 2 D)
 Operating error  ± (3 % of R + 3 D)
 Operating range of use [V] > 3,0 ÷ 130,0 
 Input resistance MΩ  1,1

External voltage AC (WELD variant only):

 Entire measuring range [V]  0,0 ÷ 90,0
 Resolution [V]  0,1
 Reference error  ± (2 % of R + 3 D)
 Operating error  ± (3 % of R + 4 D)
 Operating range of use [V]  3,0 ÷ 90,0 
 Input resistance MΩ  1,1

Welding equipment output voltage (WELD variant only):

 Entire measuring range
 of TRMS voltage[V]
 0,0 ÷ 130,0 DC
 0,0 ÷ 90,0 AC
 Entire measuring range
 of peak voltage[V]
 30,0 ÷ 130,0 DC
 30,0 ÷ 90,0 AC
 Resolution [V]  0,1
 Reference error  ± (2 % of R + 3 D)
 Operating error  ± (3 % of R + 4 D)
 Frekvency charakteristic
 of internal test circuitry
 according EN 60974-4 
 Input resistance [Ω]  200 + 5 000

1)Current clamp or three-phase adapter error has to be considered additionally.

General data:

 Protective class  II (double insulation)
 Over voltage class  CAT II/300V
 Pollution degree  2
 Degree of protection   IP 20
 Supply current  max. 16 A (it depends on tested appliance, time limit)
 Quiescent current  < 25 mA
 Dimensions (w x d x h)  250 x 195 x 50 mm
 Mass (without accessories)  1,7 kg
 Storage temeprature  -10 ÷ 50 °C
 Storage humidity  max. 70 %
 Case resistance to temperature  70 °C
 PE test  before the start of the measurement
 PC connection  USB cable

 

   Reference condition  Operating condition
 Line voltage  230 V ± 1 % / 50 Hz ± 1 %  230 V ± 10 % / 50 Hz ± 1 %
 Ambient temperature  (23 ± 2) °C  0 ÷ 40 °C
 Humidity  45 ÷ 55 % @ 23 °C  max. 75 % @ 23 °C 
 (condensation not allowed)
 Position  arbitrary  
 Elevation    max. 2 000 m

Included in the set:
The set includes all accessories necessary for testing 230 V / 50 Hz appliances equipped with a movable power supply cord.

  • The measuring instrument REVEXmax
  • P 2011 - Test lead, black, 2 m
  • P 3011 - Test tip, black
  • P 2014 - Test lead, red, 2 m (WELD variant only)
  • P 4016 - Crocodile clip, red (WELD variant only)
  • USB cable A-B
  • Spare fuse F 16 A / 500 V, 32 x 6,3 mm, 2 pcs
  • User’s Manual
  • Calibration certificate
  • Warranty card

Optional accessories:
Carrying bag:

  • P 6140 - Bag for instrument and some accessories

Measuring cables and adapters:

  • P 2012 - Test lead, blue, 2 m
  • P 2020 - Test lead, black, 5 m
  • P 3012 - Test tip, blue
  • P 3031 - Test tip (2 mm), black
  • P 4011 - Crocodile clip, black
  • P 4012 - Crocodile clip, blue
  • P 8030 - Adapter for testing PE conductor of extension power supply cords
  • P 8031 - Adapter for testing PE conductor of UPS
  • P 8090 - Adapter for testing power supply SELV with USB connector, type A and C

Special accessories:

  • P 8010 - Current clamp transformer
  • P 8015 - Three-phase adapter, 16 A socket, 5 contacts
  • P 8016 - Three-phase adapter, 16 A socket, 4 contacts
  • P 8017 - Three-phase adapter, 32 A socket, 5 contacts
  • P 8018 - Three-phase adapter, 32 A socket, 4 contacts
  • P 9011 - Wireless barcode scanner (CCD), USB 2.0.Full Speed
  • P 9025 - RFID reader, USB 2.0.Full Speed

Spare parts:

  • D 0010 - Set of 10 pcs spare fuses F 16 A / 500 V, 32 x 6,3 mm