ZEROLINE 60

ZEROLINE 60 - high precision fault loop imedance and line impedance measurement

 

 Features:

- Fault loop impedance measurement, resolution 0,001 Ω
- Line impedance measurement, resolution 0,001 Ω
- Fault loop resistance, no trip-out of RCD in RCD protected installation
- Max. value of Z/R - value which takes into consideration operating error of the ZEROLINE 60
- Prospective short-circuit current
- Earth resistance (substitute method)
- AC voltage and frequency
- Automatic check of dangerous voltage on PE
- Automatic check, if test leads are properly connected to tested installation
- Automatic exchange of L/N terminals, if L/N test leads are connected reversely to tested installation
- Automatic protection against overheating of internal power circuits

Download manual

Technical specification:

 Measuring range [Ω]  0,000 - 1,500 (I test = 30A)
 0,000 - 3,000 (I test = 20A)
 0,000 - 5,000 (I test = 10A)
 Operating range of use [Ω]
 (according to EN 61557 - 3)
 0,038 - 1,500 (I test = 30A)
 0,040 - 3,000 (I test = 20A)
 0,060 - 5,000 (I test = 10A)
 Resolution [Ω]  0,001 
 Reference error  ± (2 % R + 8 D)*   (Itest = 30A)
 ± (3 % R + 8 D)*   (Itest = 20A)
 ± (3 % R + 10 D)* (Itest = 10A)
 Operating error  ± (3 % R + 10 D)* (Itest = 30A)
 ± (4 % R + 10 D)* (Itest = 20A)
 ± (4 % R + 15 D)* (Itest = 10A)
 Test current (at 230 V / 50 Hz)  selectable: 10 A, 20 A, 30 A

Fault loop resistance - quick method:

 Measuring range [Ω]  0,00 - 20,00
 Operating range of use [Ω]
 (according to EN 61557 - 3)
 0,20 - 20,00
 Resolution [Ω]  0,01 
 Reference error  ± (3 % R + 5 D)*
 Operating error  ± (4 % R + 5 D)*
 Test current (at 230 V / 50 Hz)  10 A

Fault loop resistance - no trip-out of RCD in RCD protected installation:

 Measuring range [Ω]  0,00 - 20,00
 Operating range of use [Ω]
 (according to EN 61557 - 3)
 0,42 - 20,00
 Resolution [Ω]  0,01 
 Reference error  ± (5 % R + 8 D)*
 Operating error  ± (6 % R + 10 D)*
 Test current (at 230 V / 50 Hz)  10 A

Line impedance:

 Measuring range [Ω]  0,000 - 5,000
 Operating range of use [Ω]
 (according to EN 61557 - 3)
 0,057 - 5,000
 Resolution [Ω]  0,001 
 Reference error  ± (2,5 % R + 10 D)*
 Operating error  ± (3,5 % R + 15 D)*
 Test current (at 230 V / 400 V, 50 Hz)  10 A / 18 A

Line resstance - quick method:

 Measuring range [Ω]  0,00 - 20,00
 Operating range of use [Ω]
 (according to EN 61557 - 3)
 0,20 - 20,00
 Resolution [Ω]  0,01 
 Reference error  ± (3 % R + 5 D)*
 Operating error  ± (4 % R + 5 D)*
 Test current (at 230 V / 400 V, 50 Hz)  10 A / 18 A

Voltage L-PE, L-N, L-L:

 Measuring range [V]  200 - 440
 Resolution [V]  1 
 Reference error  ± (2 % R + 3 D)*
 Operating error  ± (3 % R + 5 D)*

Frequency:

 Measuring range [Hz]  48,00 - 52,00
 Resolution [Hz]  0,01 
 Reference error  ± (2 % R + 10 D)*
 Operating error  ± (3 % R + 10 D)*

General:

 Line voltage  200 V - 440 V / 50 Hz
 Protective class  II (double insulation)
 Over voltage class  CAT III / 300 V
 Polution degree  2
 Degree of protection  IP 40
 Dimensions  150 mm x 190 mm x 70 mm
 Mass  about 1,6 kg

 * R: reading, D: digit

Included in the set: ZEROLINE 60, test cable (6-wires), crocodile clip black, crocodile clip green/yellow, test tip black, test tip blue, neck strip, calibration certificate, instruction manual.

Optional accessories:

 P 6120  Bag for the instrument and for some accessories
 P 2071  Test cable with 230V Euro/Schuko plug
 P 4011  Crocodile clip, black
 P 4013  Crocodile clip, green/yellow
 P 3011  Test tip, black
 P 3012  Test tip, blue

up 

 

Odběr novinek
Naši partneři
  partneri metrel partneri pjp
Spřátelené stránky: partneri rawet